| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| IBM Security Identity Manager Adapters 6.0 and 7.0 does not perform an authentication check for a critical resource or functionality allowing anonymous users access to protected areas. IBM X-Force ID: 128621. |
| OSRAM SYLVANIA Osram Lightify Home before 2016-07-26 allows remote attackers to execute arbitrary commands via TCP port 4000. |
| ACTi cameras including the D, B, I, and E series using firmware version A1D-500-V6.11.31-AC fail to properly restrict access to the factory reset page. An unauthenticated, remote attacker can exploit this vulnerability by directly accessing the http://x.x.x.x/setup/setup_maintain_firmware-default.html page. This will allow an attacker to perform a factory reset on the device, leading to a denial of service condition or the ability to make use of default credentials (CVE-2017-3186). |
| The admin terminal in Hawt.io does not require authentication, which allows remote attackers to execute arbitrary commands via the k parameter. |
| A resource-permission flaw was found in the openstack-tripleo-heat-templates package where ceph.client.openstack.keyring is created as world-readable. A local attacker with access to the key could read or modify data on Ceph cluster pools for OpenStack as though the attacker were the OpenStack service, thus potentially reading or modifying data in an OpenStack Block Storage volume. |
| A Missing Authentication for Critical Function issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 or prior, and InTouch Machine Edition v8.0 SP2 or prior. InduSoft Web Studio provides the capability for an HMI client to trigger script execution on the server for the purposes of performing customized calculations or actions. A remote malicious entity could bypass the server authentication and trigger the execution of an arbitrary command. The command is executed under high privileges and could lead to a complete compromise of the server. |
| A Missing Authentication for Critical Function issue was discovered in OPW Fuel Management Systems SiteSentinel Integra 100, SiteSentinel Integra 500, and SiteSentinel iSite ATG consoles with the following software versions: older than V175, V175-V189, V191-V195, and V16Q3.1. An attacker may create an application user account to gain administrative privileges. |
| An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Lack of authentication for remote service gives access to application set up and configuration. |
| An issue was discovered in Logpoint before 7.5.0. An endpoint used by Distributed Logpoint Setup was exposed, allowing unauthenticated attackers to bypass CSRF protections and authentication. |
| Aethon TUG Home Base Server versions prior to version 24 are affected by un unauthenticated attacker who can freely access hashed user credentials. |
| A specially crafted script could cause the DeltaV Distributed Control System Controllers (All Versions) to restart and cause a denial-of-service condition. |
| A vulnerability was found in CodeAstro House Rental Management System 1.0. It has been rated as problematic. Affected by this issue is some unknown functionality of the file booking.php/owner.php/tenant.php. The manipulation leads to missing authentication. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-255392. |
| AVEVA System Platform versions 2017 through 2020 R2 P01 does not perform any authentication for functionality that requires a provable user identity. |
|
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges. An attacker could use this to create a denial-of-service state or escalate their own privileges.
|
| Fresenius Kabi Agilia SP MC WiFi vD25 and prior has a default configuration page accessible without authentication. An attacker may use this functionality to change the exposed configuration values such as network settings. |
| Emerson OpenEnterprise versions through 3.3.4 may allow an attacker to run an arbitrary commands with system privileges or perform remote code execution via a specific communication service. |
| Power Line Communications PLC4TRUCKS J2497 trailer brake controllers implement diagnostic functions which can be invoked by replaying J2497 messages. There is no authentication or authorization for these functions. |
| Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send certain commands to a specific port without authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to obtain full file-system access and remote code execution. |
| When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send a certain command to a specific port without authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to shut down a specific service. |
| When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send certain XML messages to a specific port without proper authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to read and modify the affected product’s configuration. |