Export limit exceeded: 421024 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (823 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2011-3143 | 2 Aveva, Schneider-electric | 3 Clearscada, Scx 67, Scx 68 | 2025-04-11 | N/A |
| Use-after-free vulnerability in Control Microsystems ClearSCADA 2005, 2007, and 2009 before R2.3 and R1.4, as used in SCX before 67 R4.5 and 68 R3.9, allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via unspecified long strings that trigger heap memory corruption. | ||||
| CVE-2012-0930 | 1 Schneider-electric | 1 Modicon Quantum Plc | 2025-04-11 | 6.1 Medium |
| Cross-site scripting (XSS) vulnerability in Schneider Electric Modicon Quantum PLC allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. | ||||
| CVE-2013-0658 | 1 Schneider-electric | 1 Accutech Manager | 2025-04-11 | N/A |
| Heap-based buffer overflow in RFManagerService.exe in Schneider Electric Accutech Manager 2.00.1 and earlier allows remote attackers to execute arbitrary code via a crafted HTTP request. | ||||
| CVE-2011-4034 | 1 Schneider-electric | 3 Citecthistorian, Citectscada Reports, Vijeo Historian | 2025-04-11 | N/A |
| Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to execute arbitrary code or cause a denial of service via unspecified vectors. | ||||
| CVE-2013-0663 | 1 Schneider-electric | 3 Modicon M340, Modicon Premium, Modicon Quantum Plc | 2025-04-11 | N/A |
| Cross-site request forgery (CSRF) vulnerability on the Schneider Electric Quantum 140NOE77111, 140NOE77101, and 140NWM10000; M340 BMXNOC0401, BMXNOE0100x, and BMXNOE011xx; and Premium TSXETY4103, TSXETY5103, and TSXWMY100 PLC modules allows remote attackers to hijack the authentication of arbitrary users for requests that execute commands, as demonstrated by modifying HTTP credentials. | ||||
| CVE-2013-6143 | 1 Schneider-electric | 1 Telvent Sage 3030 Firmware | 2025-04-11 | N/A |
| The Schneider Electric Telvent SAGE 3030 RTU with firmware C3413-500-001D3_P4 and C3413-500-001F0_PB allows remote attackers to cause a denial of service (temporary outage and CPU consumption) via malformed DNP3 traffic. | ||||
| CVE-2013-2782 | 1 Schneider-electric | 2 Tburjr900, Tburjr900 Firmware | 2025-04-11 | N/A |
| Schneider Electric Trio J-Series License Free Ethernet Radio with firmware 3.6.0 through 3.6.3 uses the same AES encryption key across different customers' installations, which makes it easier for remote attackers to defeat cryptographic protection mechanisms by leveraging knowledge of this key from another installation. | ||||
| CVE-2013-2762 | 1 Schneider-electric | 1 Magelis Xbt Hmi | 2025-04-11 | N/A |
| The Schneider Electric Magelis XBT HMI controller has a default password for authentication of configuration uploads, which makes it easier for remote attackers to bypass intended access restrictions via crafted configuration data. | ||||
| CVE-2013-3075 | 2 Mitsubishi-automation, Schneider-electric | 3 Mitsubishi Mx Component, Citectfacilities, Citectscada | 2025-04-11 | N/A |
| Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control. | ||||
| CVE-2013-2824 | 1 Schneider-electric | 4 Citectscada, Powerlogic Scada, Struxureware Powerscada Expert and 1 more | 2025-04-11 | N/A |
| Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to cause a denial of service via a crafted packet. | ||||
| CVE-2023-3001 | 1 Schneider-electric | 1 Igss Dashboard | 2025-03-05 | 7.8 High |
| A CWE-502: Deserialization of Untrusted Data vulnerability exists in the Dashboard module that could cause an interpretation of malicious payload data, potentially leading to remote code execution when an attacker gets the user to open a malicious file. | ||||
| CVE-2022-34755 | 1 Schneider-electric | 1 Easergy Builder Installer | 2025-03-03 | 6.3 Medium |
| A CWE-427 - Uncontrolled Search Path Element vulnerability exists that could allow an attacker with a local privileged account to place a specially crafted file on the target machine, which may give the attacker the ability to execute arbitrary code during the installation process initiated by a valid user. Affected Products: Easergy Builder Installer (1.7.23 and prior) | ||||
| CVE-2023-25548 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2025-03-03 | 8.8 High |
| A CWE-863: Incorrect Authorization vulnerability exists that could allow access to device credentials on specific DCE endpoints not being properly secured when a hacker is using a low privileged user. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior) | ||||
| CVE-2023-25552 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2025-03-03 | 8.1 High |
| A CWE-862: Missing Authorization vulnerability exists that could allow viewing of unauthorized content, changes or deleting of content, or performing unauthorized functions when tampering the Device File Transfer settings on DCE endpoints. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior) | ||||
| CVE-2023-25549 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2025-03-03 | 7.2 High |
| A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows for remote code execution when using a parameter of the DCE network settings endpoint. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior) | ||||
| CVE-2023-4516 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-27 | 7.8 High |
| A CWE-306: Missing Authentication for Critical Function vulnerability exists in the IGSS Update Service that could allow a local attacker to change update source, potentially leading to remote code execution when the attacker force an update containing malicious content. | ||||
| CVE-2023-5402 | 1 Schneider-electric | 1 C-bus Toolkit | 2025-02-27 | 9.8 Critical |
| A CWE-269: Improper Privilege Management vulnerability exists that could cause a remote code execution when the transfer command is used over the network. | ||||
| CVE-2023-5399 | 1 Schneider-electric | 1 Spacelogic C-bus Toolkit | 2025-02-27 | 9.8 Critical |
| A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause tampering of files on the personal computer running C-Bus when using the File Command. | ||||
| CVE-2023-5391 | 1 Schneider-electric | 3 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports, Ecostruxure Power Scada Operation With Advanced Reports | 2025-02-27 | 9.8 Critical |
| A CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker to execute arbitrary code on the targeted system by sending a specifically crafted packet to the application. | ||||
| CVE-2023-25551 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2025-02-12 | 6.1 Medium |
| A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE file upload endpoint when tampering with parameters over HTTP. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior) | ||||