Search Results (3710 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-10364 1 Evertz 1 3080ipx 2026-04-15 N/A
The Evertz SDVN 3080ipx-10G is a High Bandwidth Ethernet Switching Fabric for Video Application. This device exposes a web management interface on port 80. This web management interface can be used by administrators to control product features, setup network switching, and register license among other features. The application has been developed in PHP with the webEASY SDK, also named ‘ewb’ by Evertz. This web interface has two endpoints that are vulnerable to arbitrary command injection (CVE-2025-4009, CVE-2025-10364) and the authentication mechanism has a flaw leading to authentication bypass (CVE-2025-10365). CVE-2025-4009 covers the command injection in feature-transfer-import.php CVE-2025-10364 covers the command injection in feature-transfer-export.php Remote unauthenticated attackers can gain arbitrary command execution with elevated privileges ( root ) on affected devices. This level of access could lead to serious business impact such as the interruption of media streaming, modification of media being streamed, alteration of closed captions being generated, among others.
CVE-2025-10365 1 Evertz 1 3080ipx 2026-04-15 N/A
The Evertz SDVN 3080ipx-10G is a High Bandwidth Ethernet Switching Fabric for Video Application. This device exposes a web management interface on port 80. This web management interface can be used by administrators to control product features, setup network switching, and register license among other features. The application has been developed in PHP with the webEASY SDK, also named ‘ewb’ by Evertz. This web interface has two endpoints that are vulnerable to arbitrary command injection (CVE-2025-4009, CVE-2025-10364) and the authentication mechanism has a flaw leading to authentication bypass (CVE-2025-10365). Remote unauthenticated attackers can gain arbitrary command execution with elevated privileges ( root ) on affected devices. This level of access could lead to serious business impact such as the interruption of media streaming, modification of media being streamed, alteration of closed captions being generated, among others.
CVE-2025-10460 1 Beims 1 Contractorweb.net 2026-04-15 N/A
A SQL Injection vulnerability on an endpoint in BEIMS Contractor Web, a legacy product that is no longer maintained or patched by the vendor, allows an unauthorised user to retrieve sensitive database contents via unsanitized parameter input. This vulnerability occurs due to improper input validation on /BEIMSWeb/contractor.asp endpoint and successful exploitation requires a contractor.asp endpoint open to the internet. This vulnerability allows attackers to execute arbitrary SQL commands, compromising the confidentiality, integrity and potentially the availability of the database.  Version 5.7.139  has been confirmed as vulnerable. Other versions have not been confirmed by the vendor and users should assume that all versions of BEIMS Contractor Web may be impacted until further guidance is provided by the vendor.
CVE-2024-48919 1 Cursor 1 Cursor 2026-04-15 N/A
Cursor is a code editor built for programming with AI. Prior to Sep 27, 2024, if a user generated a terminal command via Cursor's Terminal Cmd-K/Ctrl-K feature and if the user explicitly imported a malicious web page into the Terminal Cmd-K prompt, an attacker with control over the referenced web page could have a significant chance of influencing a language model to output arbitrary commands for execution in the user's terminal. This scenario would require the user explicitly opt-in to including the contents of a compromised webpage, and it would require that the attacker display prompt injection text in the the contents of the compromised webpage. A server-side patch to not stream back newlines or control characters was released on September 27, 2024, within two hours of the issue being reported. Additionally, Cursor 0.42 includes client-side mitigations to prevent any newline or control character from being streamed into the terminal directly. It also contains a new setting, `"cursor.terminal.usePreviewBox"`, which, if set to true, streams the response into a preview box whose contents then have to be manually accepted before being inserted into the terminal. This setting is useful if you're working in a shell environment where commands can be executed without pressing enter or any control character. The patch has been applied server-side, so no additional action is needed, even on older versions of Cursor. Separately, Cursor's maintainers also recommend, as best practice, to only include trusted pieces of context in prompts.
CVE-2021-4470 2 Tg8, Togrow 2 Tg8 Firewall, Tg8 Firewall 2026-04-15 N/A
TG8 Firewall contains a pre-authentication remote code execution vulnerability in the runphpcmd.php endpoint. The syscmd POST parameter is passed directly to a system command without validation and executed with root privileges. A remote, unauthenticated attacker can supply crafted values to execute arbitrary operating system commands as root, resulting in full device compromise.
CVE-2025-27519 2026-04-15 N/A
Cognita is a RAG (Retrieval Augmented Generation) Framework for building modular, open source applications for production by TrueFoundry. A path traversal issue exists at /v1/internal/upload-to-local-directory which is enabled when the Local env variable is set to true, such as when Cognita is setup using Docker. Because the docker environment sets up the backend uvicorn server with auto reload enabled, when an attacker overwrites the /app/backend/__init__.py file, the file will automatically be reloaded and executed. This allows an attacker to get remote code execution in the context of the Docker container. This vulnerability is fixed in commit a78bd065e05a1b30a53a3386cc02e08c317d2243.
CVE-2025-46352 2026-04-15 9.8 Critical
The CS5000 Fire Panel is vulnerable due to a hard-coded password that runs on a VNC server and is visible as a string in the binary responsible for running VNC. This password cannot be altered, allowing anyone with knowledge of it to gain remote access to the panel. Such access could enable an attacker to operate the panel remotely, potentially putting the fire panel into a non-functional state and causing serious safety issues.
CVE-2025-64119 1 Nuvation Energy 1 Battery Management System 2026-04-15 N/A
A vulnerability in Nuvation Battery Management System allows Authentication Bypass.This issue affects Battery Management System: through 2.3.9.
CVE-2025-2566 2026-04-15 N/A
Kaleris NAVIS N4 ULC (Ultra Light Client) contains an unsafe Java deserialization vulnerability. An unauthenticated attacker can make specially crafted requests to execute arbitrary code on the server.
CVE-2020-37135 3 Amss++ Project, Amss\+\+ Project, Amssplus 3 Amss++, Amss\+\+, Amss Plus 2026-04-15 7.5 High
AMSS++ 4.7 contains an authentication bypass vulnerability that allows attackers to access administrative accounts using hardcoded credentials. Attackers can log in with the default admin username and password '1234' to gain unauthorized administrative access to the system.
CVE-2025-41438 2026-04-15 9.8 Critical
The CS5000 Fire Panel is vulnerable due to a default account that exists on the panel. Even though it is possible to change this by SSHing into the device, it has remained unchanged on every installed system observed. This account is not root but holds high-level permissions that could severely impact the device's operation if exploited.
CVE-2024-43653 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2025-24971 2026-04-15 N/A
DumpDrop is a stupid simple file upload application that provides an interface for dragging and dropping files. An OS Command Injection vulnerability was discovered in the DumbDrop application, `/upload/init` endpoint. This vulnerability could allow an attacker to execute arbitrary code remotely when the **Apprise Notification** enabled. This issue has been addressed in commit `4ff8469d` and all users are advised to patch. There are no known workarounds for this vulnerability.
CVE-2025-1087 2026-04-15 N/A
Kong Insomnia Desktop Application before 11.0.2 contains a template injection vulnerability that allows attackers to execute arbitrary code. The vulnerability exists due to insufficient validation of user-supplied input when processing template strings, which can lead to arbitrary JavaScript execution in the context of the application.
CVE-2024-12297 2026-04-15 N/A
Moxa’s Ethernet switch is vulnerable to an authentication bypass because of flaws in its authorization mechanism. Although both client-side and back-end server verification are involved in the process, attackers can exploit weaknesses in its implementation. These vulnerabilities may enable brute-force attacks to guess valid credentials or MD5 collision attacks to forge authentication hashes, potentially compromising the security of the device.
CVE-2024-7093 1 Netflix 1 Dispatch 2026-04-15 N/A
Dispatch's notification service uses Jinja templates to generate messages to users. Jinja permits code execution within blocks, which were neither properly sanitized nor sandboxed. This vulnerability enables users to construct command line scripts in their custom message templates, which are then executed whenever these notifications are rendered and sent out.
CVE-2017-20198 2026-04-15 N/A
The Marathon UI in DC/OS < 1.9.0 allows unauthenticated users to deploy arbitrary Docker containers. Due to improper restriction of volume mount configurations, attackers can deploy a container that mounts the host's root filesystem (/) with read/write privileges. When using a malicious Docker image, the attacker can write to /etc/cron.d/ on the host, achieving arbitrary code execution with root privileges. This impacts any system where the Docker daemon honors Marathon container configurations without policy enforcement.
CVE-2025-22470 1 Sato 4 Cl4nx-j Plus, Cl4nx Plus, Cl6nx-j Plus and 1 more 2026-04-15 N/A
CL4/6NX Plus and CL4/6NX-J Plus (Japan model) with the firmware versions prior to 1.15.5-r1 allow crafted dangerous files to be uploaded. An arbitrary Lua script may be executed on the system with the root privilege.
CVE-2025-24522 1 Kunbus 1 Revpi Os 2026-04-15 10 Critical
KUNBUS Revolution Pi OS Bookworm 01/2025 is vulnerable because authentication is not configured by default for the Node-RED server. This can give an unauthenticated remote attacker full access to the Node-RED server where they can run arbitrary commands on the underlying operating system.
CVE-2025-24480 2026-04-15 N/A
A Remote Code Execution Vulnerability exists in the product and version listed above. The vulnerability is due to lack of input sanitation and could allow a remote attacker to run commands or code as a high privileged user.