| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An RPC service, which is part of exos 9300, is reachable on port 4000, run by the process FSMobilePhoneInterface.exe. This service is used for interprocess communication between services and the Kaba exos 9300 GUI, containing status information about the Access Managers. Interacting with the service does not require any authentication. Therefore, it is possible to send arbitrary status information about door contacts etc. without prior authentication. |
| IXON B.V. IXrouter IX2400 (Industrial Edge Gateway) v3.0 was discovered to contain hardcoded root credentials stored in the non-volatile flash memory. This vulnerability allows physically proximate attackers to gain root access via UART or SSH. |
| The default password for the extended admin user mode in the application U9ExosAdmin.exe ("Kaba 9300 Administration") is hard-coded in multiple locations as well as documented in the locally stored user documentation. |
| Use of Hard-coded Credentials in Kiloview NDI allows un-authenticated users to bypass authenticationThis issue affects Kiloview NDI N3, N3-s, N4, N20, N30, N40 and was fixed in Firmware version 2.02.0227 .
|
| Vulnerabilities* in ActADUR local server product, developed and maintained by ProTNS, allows Remote Code Inclusion on host systems.
* vulnerabilities:
*
Improper Neutralization of Special Elements used in a Command ('Command Injection')
* Use of Hard-coded Credentials
* Improper Authentication
* Binding to an Unrestricted IP Address
The vulnerability has been rated as critical.This issue affects ActADUR: from v2.0.1.9 before v2.0.2.0., hence updating to version v2.0.2.0. or above is required. |
| The `/etc/passwd` and `/etc/shadow` files reveal hard-coded password hashes for the operating system "root" user. The credentials are shipped with the update files. There is no option for deleting or changing their passwords for an enduser. An attacker can use the credentials to log into the device. Authentication can be performed via SSH backdoor or likely via physical access (UART shell). |
| There are several scripts in the web interface that are accessible via undocumented hard-coded credentials. The scripts provide access to additional administrative/debug functionality and are likely intended for debugging during development and provides an additional attack surface. |
| In the IROAD APK 5.2.5, there are Hardcoded Credentials in the APK for ports 9091 and 9092. The mobile application for the dashcam contains hardcoded credentials that allow an attacker on the local Wi-Fi network to access API endpoints and retrieve sensitive device information, including live and recorded footage. |
| hippo4j 1.0.0 to 1.5.0, uses a hard-coded secret key in its JWT (JSON Web Token) creation. This allows attackers with access to the source code or compiled binary to forge valid access tokens and impersonate any user, including privileged ones such as "admin". The vulnerability poses a critical security risk in systems where authentication and authorization rely on the integrity of JWTs. |
| Ubiquiti U7-Pro 7.0.35 was discovered to contain a hardcoded password vulnerability in /etc/shadow, which allows attackers to log in as root. NOTE: this is disputed by the Supplier because the observation only established that a password is present in a firmware image; however, the device cannot be deployed without setting a new password during installation. |
| The WorkExaminer Professional server installation comes with an FTP server that is used to receive the client logs on TCP port 12304. An attacker with network access to this port can use weak hardcoded credentials to login to the FTP server and modify or read data, log files and gain remote code execution as NT Authority\SYSTEM on the server by exchanging accessible service binaries in the WorkExaminer installation directory (e.g. "C:\Program File (x86)\Work Examiner Professional Server"). |
| HI-SCAN 6040i Hitrax HX-03-19-I was discovered to contain hardcoded credentials for access to vendor support and service access. |
| Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to disclose information such as generated power and electricity sold back to the grid stored in the product, tamper with or destroy stored or configured information in the product, or cause a Denial-of-Service (DoS) condition on the product, by using hardcoded user ID and password common to the product series obtained by exploiting CVE-2025-5022. The affected products discontinued in 2015, support ended in 2020. |
| Hard-coded credentials were included as part of the application binary.
These credentials served as part of the application authentication flow
and communication with the mobile application. An attacker could access
unauthorized information. |
| A vulnerability classified as critical has been found in IROAD X5 Mobile App up to 5.2.5 on Android. Affected is an unknown function of the component API Endpoint. The manipulation leads to hard-coded credentials. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability classified as critical was found in IROAD Dash Cam X5 and Dash Cam X6 up to 20250308. Affected by this vulnerability is an unknown functionality of the component Device Pairing. The manipulation leads to hard-coded credentials. Access to the local network is required for this attack to succeed. The complexity of an attack is rather high. The exploitation appears to be difficult. The vendor was contacted early about this disclosure but did not respond in any way. |
| An unauthenticated SQL injection vulnerability exists in Pandora FMS version 5.0 SP2 and earlier. The mobile/index.php endpoint fails to properly sanitize user input in the loginhash_data parameter, allowing attackers to extract administrator credentials or active session tokens via crafted requests. This occurs because input is directly concatenated into an SQL query without adequate validation, enabling SQL injection. After authentication is bypassed, a second vulnerability in the File Manager component permits arbitrary PHP file uploads. The file upload functionality does not enforce MIME-type or file extension restrictions, allowing authenticated users to upload web shells into a publicly accessible directory and achieve remote code execution. |
| All the Toshiba printers contain a shell script using the same hardcoded key to encrypt logs. An attacker can decrypt the encrypted files using the hardcoded key. This vulnerability can be executed in combination with other vulnerabilities and difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the "Base Score" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point.
https://www.toshibatec.com/contacts/products/
As for the affected products/models/versions, see the reference URL. |
| AMSS++ 4.7 contains an authentication bypass vulnerability that allows attackers to access administrative accounts using hardcoded credentials. Attackers can log in with the default admin username and password '1234' to gain unauthorized administrative access to the system. |
| Default credentials were present in the web portal for Airpointer 2.4.107-2, allowing an unauthenticated malicious actor to log in via the web portal |