| Shenzhen Tuoshi NR500-EA RG500UEAABxCOMSLICv3.4.2731.16.43 devices enable the SSH service by default. There is a hidden hard-coded root account that cannot be disabled in the GUI. |
| Hard-coded login credentials were found in HPE Networking Instant On Access Points, allowing anyone with knowledge of it to bypass normal device authentication. Successful exploitation could allow a remote attacker to gain administrative access to the system. |
| Neye3C v4.5.2.0 was discovered to contain a hardcoded encryption key in the firmware update mechanism. |
| Use of Hard-coded Credentials in Kiloview NDI allows un-authenticated users to bypass authenticationThis issue affects Kiloview NDI N3, N3-s, N4, N20, N30, N40 and was fixed in Firmware version 2.02.0227 .
|
| A vulnerability in the .sdd file allows an attacker to read default passwords stored in plain text within the code. By exploiting these plaintext credentials, an attacker can log into affected SICK products as an “Authorized Client” if the customer has not changed the default password. |
| This vulnerability exists in ZKTeco WL20 due to hard-coded private key stored in plaintext within the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and analyzing the binary data to retrieve private key stored in the firmware of the targeted device.
Successful exploitation of this vulnerability could allow the attacker to perform unauthorized decryption of sensitive data and Man-in-the-Middle (MitM) attacks on the targeted device. |
| Use of hard-coded credentials issue exists in ZWX-2000CSW2-HN prior to 0.3.19 and ZWX-2000CS2-HN firmware all versions. If this vulnerability is exploited, an attacker may tamper with the settings of the device by obtaining the credentials. This vulnerability is caused by an insufficient fix for CVE-2024-39838. |
| NixOS's Onlyoffice is a software suite that offers online and offline tools for document editing, collaboration, and management. In versions from 22.11 to before 25.05 and versions before Unstable 25.11, a hard-coded secret was used in the NixOS module for the OnlyOffice document server to protect its file cache. An attacker with knowledge of an existing revision ID could use this secret to obtain a document. In practice, an arbitrary revision ID should be hard to obtain. The primary impact is likely the access to known documents from users with expired access. This issue was resolved in NixOS unstable version 25.11 and version 25.05. |
| Clinic Image System developed by Changing contains hard-coded Credentials, allowing unauthenticated remote attackers to log into the system using administrator credentials embedded in the source code. |
| An issue was discovered in the G-Net GNET APK 2.6.2. Hardcoded credentials exist in in APK for ports 9091 and 9092. The GNET mobile application contains hardcoded credentials that provide unauthorized access to the dashcam's API endpoints on ports 9091 and 9092. Once the GNET SSID is connected to, the attacker sends a crafted authentication command with TibetList and 000000 to list settings of the dashcam at port 9091. There's a separate set of credentials for port 9092 (stream) that is also exposed in cleartext: admin + tibet. For settings, the required credentials are adim + 000000. |
| A vulnerability classified as problematic was found in Audi UTR Dashcam 2.0. Affected by this vulnerability is an unknown functionality of the component Video Stream Handler. The manipulation leads to hard-coded credentials. The attack can only be initiated within the local network. The exploit has been disclosed to the public and may be used. Upgrading to version 2.89 and 2.90 is able to address this issue. It is recommended to upgrade the affected component. The vendor was contacted early about these issues and acted very professional. Version 2.89 is fixing this issue for new customers and 2.90 is going to fix it for existing customers. |
| This vulnerability exists in Digisol DG-GR6821AC Router due to hard-coded Root Access Credentials in system configuration of the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and analyzing the binary data to obtain the stored root access credentials.
Successful exploitation of this vulnerability could allow the attacker to gain admin access to the targeted device. |
| Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to disclose information such as generated power and electricity sold back to the grid stored in the product, tamper with or destroy stored or configured information in the product, or cause a Denial-of-Service (DoS) condition on the product, by using hardcoded user ID and password common to the product series obtained by exploiting CVE-2025-5022. The affected products discontinued in 2015, support ended in 2020. |
| Dormakaba provides the software FWServiceTool to update the firmware version of the Access Managers via the network. The firmware in some instances is provided in an encrypted ZIP file. Within this tool, the password used to decrypt the ZIP and extract the firmware is set statically and can be extracted. This password was valid for multiple observed firmware versions. |
| An insecure sensitive key storage issue was found in MyASUS. potentially allowing unauthorized actor to obtain a token that could be used to communicate with certain services.
Refer to the 'Security Update for for MyASUS' section on the ASUS Security Advisory for more information. |
| The ArchiverSpaApi ASP.NET application uses a hard-coded JWT signing key. An unauthenticated remote attacker can generate and use a verifiable JWT token to access protected ArchiverSpaApi URL endpoints. |
| Ecovacs Home Android and iOS Mobile Applications up to version 3.3.0 contained embedded access keys and secrets for Alibaba Object Storage Service (OSS), leading to sensitive data disclosure. |
| Adtec Digital SignEdje Digital Signage Player v2.08.28 contains multiple hardcoded default credentials that allow unauthenticated remote access to web, telnet, and SSH interfaces. Attackers can exploit these credentials to gain root-level access and execute system commands across multiple Adtec Digital product versions. |
| Netis E1+ version 1.2.32533 contains a hardcoded root account vulnerability that allows unauthenticated attackers to access the device with predefined credentials. Attackers can leverage the embedded root account with a crackable password to gain full administrative access to the network device. |
| We observed that Intellispace Portal binaries doesn’t have any protection mechanisms to prevent reverse engineering. Specifically, the app’s code is not obfuscated, and no measures are in place to protect against decompilation, disassembly, or debugging. As a result, attackers can reverse-engineer the application to gain insights into its internal workings, which can potentially lead to the discovery of sensitive information, business logic flaws, and other vulnerabilities.
Utilizing this flaw, the attacker was able to identify the Hardcoded credentials from PortalUsersDatabase.dll, which contains .NET remoting definition. Inside the namespace PortalUsersDatabase, the class Users contains the functions CreateAdmin and CreateService that are used to initialize accounts in the Portal service. Both CreateAdmin and CreateService functions contain a hardcoded encrypted password along with its respective salt that are set with the function SetInitialPasswordAndSalt.