Export limit exceeded: 417886 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (107896 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-2708 | 1 Tenda | 2 Ac10u, Ac10u Firmware | 2024-12-12 | 8.8 High |
| A vulnerability was found in Tenda AC10U 15.03.06.49 and classified as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257459. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-2706 | 1 Tenda | 2 Ac10u, Ac10u Firmware | 2024-12-12 | 8.8 High |
| A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.49. This affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257457 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-2705 | 1 Tenda | 2 Ac10u, Ac10u Firmware | 2024-12-12 | 8.8 High |
| A vulnerability, which was classified as critical, has been found in Tenda AC10U 1.0/15.03.06.49. Affected by this issue is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257456. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-2704 | 1 Tenda | 2 Ac10u, Ac10u Firmware | 2024-12-12 | 8.8 High |
| A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49. Affected by this vulnerability is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257455. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-2703 | 1 Tenda | 2 Ac10u, Ac10u Firmware | 2024-12-12 | 8.8 High |
| A vulnerability classified as critical has been found in Tenda AC10U 15.03.06.49. Affected is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257454 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2023-2492 | 1 Querywall Plug\'n Play Firewall Project | 1 Querywall Plug\'n Play Firewall | 2024-12-12 | 7.2 High |
| The QueryWall: Plug'n Play Firewall WordPress plugin through 1.1.1 does not properly sanitise and escape a parameter before using it in a SQL statement, leading to a SQL injection exploitable by high privilege users such as admin. | ||||
| CVE-2023-2359 | 1 Themepunch | 1 Slider Revolution | 2024-12-12 | 8.8 High |
| The Slider Revolution WordPress plugin through 6.6.12 does not check for valid image files upon import, leading to an arbitrary file upload which may be escalated to Remote Code Execution in some server configurations. | ||||
| CVE-2023-24243 | 1 Cdata | 1 Arc | 2024-12-12 | 7.5 High |
| CData RSB Connect v22.0.8336 was discovered to contain a Server-Side Request Forgery (SSRF). | ||||
| CVE-2022-4149 | 2 Microsoft, Netskope | 2 Windows, Netskope | 2024-12-12 | 7 High |
| The Netskope client service (prior to R96) on Windows runs as NT AUTHORITY\SYSTEM which writes log files to a writable directory (C:\Users\Public\netSkope) for a standard user. The files are created and written with a SYSTEM account except one file (logplaceholder) which inherits permission giving all users full access control list. Netskope client restricts access to this file by allowing only read permissions as a standard user. Whenever the Netskope client service restarts, it deletes the logplaceholder and recreates, creating a race condition, which can be exploited by a malicious local user to create the file and set ACL permissions on the file. Once the file is created by a malicious user with proper ACL permissions, all files within C:\Users\Public\netSkope\ becomes modifiable by the unprivileged user. By using Windows pseudo-symlink, these files can be pointed to other places in the system and thus malicious users will be able to elevate privileges. | ||||
| CVE-2023-2847 | 1 Eset | 3 Cyber Security, Endpoint Antivirus, Server Security | 2024-12-12 | 7.8 High |
| During internal security analysis, a local privilege escalation vulnerability has been identified. On a machine with the affected ESET product installed, it was possible for a user with lower privileges due to improper privilege management to trigger actions with root privileges. ESET remedied this possible attack vector and has prepared new builds of its products that are no longer susceptible to this vulnerability. | ||||
| CVE-2024-43053 | 1 Qualcomm | 40 Fastconnect 6700, Fastconnect 6700 Firmware, Fastconnect 6900 and 37 more | 2024-12-12 | 7.8 High |
| Memory corruption while invoking IOCTL calls from user space to read WLAN target diagnostic information. | ||||
| CVE-2024-43052 | 1 Qualcomm | 185 205 Mobile Platform, 205 Mobile Platform Firmware, 215 Mobile Platform and 182 more | 2024-12-12 | 7.8 High |
| Memory corruption while processing API calls to NPU with invalid input. | ||||
| CVE-2024-43050 | 1 Qualcomm | 109 Aqt1000, Aqt1000 Firmware, Fastconnect 6200 and 106 more | 2024-12-12 | 7.8 High |
| Memory corruption while invoking IOCTL calls from user space to issue factory test command inside WLAN driver. | ||||
| CVE-2024-43049 | 1 Qualcomm | 38 Fastconnect 6700, Fastconnect 6700 Firmware, Fastconnect 6900 and 35 more | 2024-12-12 | 7.8 High |
| Memory corruption while invoking IOCTL calls from user space to set generic private command inside WLAN driver. | ||||
| CVE-2024-43048 | 1 Qualcomm | 104 Fastconnect 6200, Fastconnect 6200 Firmware, Fastconnect 6900 and 101 more | 2024-12-12 | 7.8 High |
| Memory corruption when invalid input is passed to invoke GPU Headroom API call. | ||||
| CVE-2024-33063 | 1 Qualcomm | 250 Ar8035, Ar8035 Firmware, Fastconnect 6900 and 247 more | 2024-12-12 | 7.5 High |
| Transient DOS while parsing the ML IE when a beacon with common info length of the ML IE greater than the ML IE inside which this element is present. | ||||
| CVE-2024-33056 | 1 Qualcomm | 662 205 Mobile Platform, 205 Mobile Platform Firmware, 315 5g Iot Modem and 659 more | 2024-12-12 | 8.4 High |
| Memory corruption when allocating and accessing an entry in an SMEM partition continuously. | ||||
| CVE-2024-33044 | 1 Qualcomm | 425 315 5g Iot Modem, 315 5g Iot Modem Firmware, Aqt1000 and 422 more | 2024-12-12 | 8.4 High |
| Memory corruption while Configuring the SMR/S2CR register in Bypass mode. | ||||
| CVE-2023-38136 | 1 Apple | 3 Ipados, Iphone Os, Watchos | 2024-12-12 | 7.8 High |
| The issue was addressed with improved memory handling. This issue is fixed in iOS 16.6 and iPadOS 16.6, watchOS 9.6. An app may be able to execute arbitrary code with kernel privileges. | ||||
| CVE-2023-38261 | 1 Apple | 3 Ipados, Iphone Os, Macos | 2024-12-12 | 7.8 High |
| The issue was addressed with improved memory handling. This issue is fixed in iOS 16.6 and iPadOS 16.6, macOS Ventura 13.5. An app may be able to execute arbitrary code with kernel privileges. | ||||