| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The parse_charstrings function in type1/t1load.c in FreeType 2 before 2.7 does not ensure that a font contains a glyph name, which allows remote attackers to cause a denial of service (heap-based buffer over-read) or possibly have unspecified other impact via a crafted file. |
| 389 Directory Server in Red Hat Enterprise Linux Desktop 6 through 7, Red Hat Enterprise Linux HPC Node 6 through 7, Red Hat Enterprise Linux Server 6 through 7, and Red Hat Enterprise Linux Workstation 6 through 7 allows remote attackers to read the default Access Control Instructions. |
| TelescopeJS before 0.15 leaks user bcrypt password hashes in websocket messages, which might allow remote attackers to obtain password hashes via a cross-site scripting attack. |
| An issue was discovered in certain Apple products. iOS before 10.3.3 is affected. Safari before 10.1.2 is affected. iCloud before 6.2.2 on Windows is affected. iTunes before 12.6.2 on Windows is affected. The issue involves the "WebKit" component. It allows attackers to bypass intended memory-read restrictions via a crafted app. |
| On Beijing Hanbang Hanbanggaoke devices, because user-controlled input is not sufficiently sanitized, sending a PUT request to /ISAPI/Security/users/1 allows an admin password change. |
| phpMyAdmin 4.0, 4.4, and 4.6 are vulnerable to a DOS weakness in the table editing functionality |
| phpMyAdmin 4.0, 4.4., and 4.6 are vulnerable to a DOS attack in the replication status by using a specially crafted table name |
| A spoofing vulnerability exists when the ASP.NET Core fails to properly sanitize web requests. |
| DP300 V500R002C00,TE60 with software V100R001C01, V100R001C10, V100R003C00, V500R002C00 and V600R006C00,TP3106 with software V100R001C06 and V100R002C00,ViewPoint 9030 with software V100R011C02, V100R011C03,eCNS210_TD with software V100R004C10,eSpace 7950 with software V200R003C00 and V200R003C30,eSpace IAD with software V300R001C07SPCa00 and V300R002C01SPCb00,eSpace U1981 with software V100R001C20, V100R001C30, V200R003C00, V200R003C20 and V200R003C30 have an input validation vulnerability.A remote attacker may exploit this vulnerability by crafting a malformed packet and sending it to the device. A successful exploit could allow the attacker to cause a denial of service or execute arbitrary code. |
| The Windows kernel in Microsoft Windows Server 2008 SP2 and R2 SP1, Windows 7 SP1, Windows 8.1, Windows Server 2012 Gold and R2, Windows RT 8.1, Windows 10 Gold, 1511, 1607, 1703, and Windows Server 2016 allows authenticated attackers to obtain sensitive information via a specially crafted document, aka "Windows Kernel Information Disclosure Vulnerability," a different vulnerability than CVE-2017-0175, CVE-2017-0220, and CVE-2017-0259. |
| The Windows kernel in Microsoft Windows 8.1, Windows Server 2012 R2, Windows RT 8.1, Windows 10 Gold, 1511, 1607, 1703, and Windows Server 2016 allows authenticated attackers to obtain sensitive information via a specially crafted document, aka "Windows Kernel Information Disclosure Vulnerability," a different vulnerability than CVE-2017-0175, CVE-2017-0220, and CVE-2017-0258. |
| A input validation vulnerability in HPE Operations Orchestration product all versions prior to 10.80, allows for the execution of code remotely. |
| OSRAM SYLVANIA Osram Lightify Home before 2016-07-26 stores a PSK in cleartext under /private/var/mobile/Containers/Data/Application. |
| The qemu-nbd server in QEMU (aka Quick Emulator), when built with the Network Block Device (NBD) Server support, allows remote attackers to cause a denial of service (segmentation fault and server crash) by leveraging failure to ensure that all initialization occurs before talking to a client in the nbd_negotiate function. |
| Microsoft Server Message Block 1.0 (SMBv1) allows an information disclosure vulnerability in the way that Microsoft Windows Server 2008 SP2 and R2 SP1, Windows 7 SP1, Windows 8.1, Windows Server 2012 Gold and R2, Windows RT 8.1, Windows 10 Gold, 1511, 1607, and 1703, and Windows Server 2016 handles certain requests, aka "Windows SMB Information Disclosure Vulnerability". This CVE ID is unique from CVE-2017-0268, CVE-2017-0270, CVE-2017-0271, CVE-2017-0274, CVE-2017-0275, and CVE-2017-0276. |
| An issue was discovered in certain Apple products. iOS before 10.3.3 is affected. Safari before 10.1.2 is affected. tvOS before 10.2.2 is affected. The issue involves the "WebKit" component. It allows remote attackers to conduct a timing side-channel attack to bypass the Same Origin Policy and obtain sensitive information via a crafted web site that uses SVG filters. |
| Microsoft Server Message Block 1.0 (SMBv1) allows an information disclosure vulnerability in the way that Microsoft Windows Server 2008 SP2 and R2 SP1, Windows 7 SP1, Windows 8.1, Windows Server 2012 Gold and R2, Windows RT 8.1, Windows 10 Gold, 1511, 1607, and 1703, and Windows Server 2016 handles certain requests, aka "Windows SMB Information Disclosure Vulnerability". This CVE ID is unique from CVE-2017-0267, CVE-2017-0270, CVE-2017-0271, CVE-2017-0274, CVE-2017-0275, and CVE-2017-0276. |
| Microsoft Server Message Block 1.0 (SMBv1) allows an information disclosure vulnerability in the way that Microsoft Windows Server 2008 SP2 and R2 SP1, Windows 7 SP1, Windows 8.1, Windows Server 2012 Gold and R2, Windows RT 8.1, Windows 10 Gold, 1511, 1607, and 1703, and Windows Server 2016 handles certain requests, aka "Windows SMB Information Disclosure Vulnerability". This CVE ID is unique from CVE-2017-0267, CVE-2017-0268, CVE-2017-0271, CVE-2017-0274, CVE-2017-0275, and CVE-2017-0276. |
| Microsoft Server Message Block 1.0 (SMBv1) allows an information disclosure vulnerability in the way that Microsoft Windows Server 2008 SP2 and R2 SP1, Windows 7 SP1, Windows 8.1, Windows Server 2012 Gold and R2, Windows RT 8.1, Windows 10 Gold, 1511, 1607, and 1703, and Windows Server 2016 handles certain requests, aka "Windows SMB Information Disclosure Vulnerability". This CVE ID is unique from CVE-2017-0267, CVE-2017-0268, CVE-2017-0270, CVE-2017-0274, CVE-2017-0275, and CVE-2017-0276. |
| EMC PowerPath Virtual (Management) Appliance 2.0, EMC PowerPath Virtual (Management) Appliance 2.0 SP1 is affected by a sensitive information disclosure vulnerability that may potentially be exploited by malicious users to compromise the affected system. |