| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
|
An authentication bypass vulnerability was identified in SMM/SMM2 and FPC that could allow an authenticated user to execute certain IPMI calls that could lead to exposure of limited system information.
|
| Missing authentication for critical function vulnerability exists in ID Link Manager and FUJITSU Software TIME CREATOR. If this vulnerability is exploited, sensitive information may be obtained and/or the information stored in the database may be altered by a remote authenticated attacker. |
| The vulnerability allows unauthenticated users to download a file containing session ID data by directly accessing the "/cgi-bin/CliniNET.prd/utils/userlogxls.pl" endpoint. |
| The paths "/cgi-bin/CliniNET.prd/utils/userlogstat.pl", "/cgi-bin/CliniNET.prd/utils/usrlogstat.pl", and "/cgi-bin/CliniNET.prd/utils/dblogstat.pl" expose data containing session IDs. |
| An issue was discovered in Atos Eviden iCare 2.7.1 through 2.7.11. The application exposes a web interface locally. In the worst-case scenario, if the application is remotely accessible, it allows an attacker to execute arbitrary commands with system privilege on the endpoint hosting the application, without any authentication. |
| Insufficient authentication in user account management in Yugabyte Platform allows local network attackers with a compromised user session to change critical security information without re-authentication. An attacker with user session and access to application can modify settings such as password and email without being prompted for the current password, enabling account takeover. |
| Improper Access Control issue in the Workflow component of Fortra's FileCatalyst allows unauthenticated users to upload arbitrary files via the order forms page. |
| An authentication bypass vulnerability exists which allows an unauthenticated attacker to control administrator backup functions, leading to compromise of passwords, secrets, and application session tokens stored by the Unified PAM. |
| The devices allow access to an unprotected endpoint that allows MPFS
file system binary image upload without authentication. The MPFS2 file
system module provides a light-weight read-only file system that can be
stored in external EEPROM, external serial flash, or internal flash
program memory. This file system serves as the basis for the HTTP2 web
server module, but is also used by the SNMP module and is available to
other applications that require basic read-only storage capabilities.
This can be exploited to overwrite the flash program memory that holds
the web server's main interfaces and execute arbitrary code. |
| The affected products allow unauthenticated access to Open Network Video Interface Forum (ONVIF) services, which may allow an attacker unauthorized access to camera configuration information. |
| Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, and Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95 allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: (1) Active Directory is used in the security setting (2) "Automatic log in" option is enabled in the security setting (3) The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account. (4) The IcoAnyGlass IIS Application Pool account is included in GENESIS64, ICONCIS Suite, and MC Works64 Security and has permission to log in. |
| Unitree Go2, G1, H1, and B2 devices through 2025-09-20 accept any handshake secret with the unitree substring. |
| An unauthenticated remote command execution vulnerability exists in Pandora FMS versions up to and including 5.0RC1 via the Anyterm web interface, which listens on TCP port 8023. The anyterm-module endpoint accepts unsanitized user input via the p parameter and directly injects it into a shell command, allowing arbitrary command execution as the pandora user. In certain versions (notably 4.1 and 5.0RC1), the pandora user can elevate privileges to root without a password using a chain involving the artica user account. This account is typically installed without a password and is configured to run sudo without authentication. Therefore, full system compromise is possible without any credentials. |
| An unauthenticated remote attacker who is aware of a MQTT topic name can send and receive messages, including GET/SET configuration commands, reboot commands and firmware updates. |
| Reolink Video Doorbell WiFi DB_566128M5MP_W allows root shell access through an unsecured UART/serial console. An attacker with physical access can connect to the exposed interface and execute arbitrary commands with root privileges. NOTE: this is disputed by the Supplier because of "certain restrictions on users privately connecting serial port cables" and because "the root user has a password and it meets the requirements of password security complexity." |
| The Iskra iHUB and iHUB Lite smart metering gateway exposes its web management interface without requiring authentication, allowing unauthenticated users to access and modify critical device settings. |
| With address book access, SMB/FTP settings could be modified, redirecting scans and possibly capturing credentials. This requires enabled scan functions and printer access. |
| Statistical Database System developed by Gotac has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to read, modify, and delete database contents with high-level privileges. |
| A code execution security issue exists in the affected product. An attacker with physical access could abuse the maintenance menu of the controller with a crafted payload. The security issue can result in arbitrary code execution. |
| SAP NetWeaver Enterprise Portal OBN does not perform proper authentication check for a particular configuration setting. As result, a non-authenticated user can set it to an undesired value causing low impact on integrity. There is no impact on confidentiality or availability of the application. |