Export limit exceeded: 398259 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (4629 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-31684 | 2026-04-15 | 3.5 Low | ||
| Incorrect access control in the fingerprint authentication mechanism of Bitdefender Mobile Security v4.11.3-gms allows attackers to bypass fingerprint authentication due to the use of a deprecated API. | ||||
| CVE-2020-12484 | 2026-04-15 | 6.4 Medium | ||
| When using special mode to connect to enterprise wifi, certain options are not properly configured and attackers can pretend to be enterprise wifi through a carefully constructed wifi with the same name, which can lead to man-in-the-middle attacks. | ||||
| CVE-2021-4461 | 1 Seeyon | 1 Zhiyuan Oa Web Application System | 2026-04-15 | N/A |
| Seeyon Zhiyuan OA Web Application System versions up to and including 7.0 SP1 improperly decode and parse the `enc` parameter in thirdpartyController.do. The decoded map values can influence session attributes without sufficient authentication/authorization checks, enabling attackers to assign a session to arbitrary user IDs. VulnCheck has observed this vulnerability being exploited in the wild as of 2025-10-30 at 00:30:40.855917 UTC. | ||||
| CVE-2025-54860 | 1 Cognex | 2 In-sight Camera Firmware, In Sight Explorer | 2026-04-15 | 7.7 High |
| Cognex In-Sight Explorer and In-Sight Camera Firmware expose a telnet-based service on port 23 in order to allow management operations on the device such as firmware upgrades and device reboot requiring an authentication. A wrong management of login failures of the service allows a denial-of-service attack, leaving the telnet service into an unreachable state. | ||||
| CVE-2024-31218 | 2026-04-15 | 9.8 Critical | ||
| Webhood is a self-hosted URL scanner used analyzing phishing and malicious sites. Webhood's backend container images in versions 0.9.0 and earlier are subject to Missing Authentication for Critical Function vulnerability. This vulnerability allows an unauthenticated attacker to send a HTTP request to the database (Pocketbase) admin API to create an admin account. The Pocketbase admin API does not check for authentication/authorization when creating an admin account when no admin accounts have been added. In its default deployment, Webhood does not create a database admin account. Therefore, unless users have manually created an admin account in the database, an admin account will not exist in the deployment and the deployment is vulnerable. Versions starting from 0.9.1 are patched. The patch creates a randomly generated admin account if admin accounts have not already been created i.e. the vulnerability is exploitable in the deployment. As a workaround, users can disable access to URL path starting with `/api/admins` entirely. With this workaround, the vulnerability is not exploitable via network. | ||||
| CVE-2025-48994 | 2026-04-15 | N/A | ||
| SignXML is an implementation of the W3C XML Signature standard in Python. When verifying signatures with X509 certificate validation turned off and HMAC shared secret set (`signxml.XMLVerifier.verify(require_x509=False, hmac_key=...`), versions of SignXML prior to 4.0.4 are vulnerable to a potential algorithm confusion attack. Unless the user explicitly limits the expected signature algorithms using the `signxml.XMLVerifier.verify(expect_config=...)` setting, an attacker may supply a signature unexpectedly signed with a key other than the provided HMAC key, using a different (asymmetric key) signature algorithm. Starting with SignXML 4.0.4, specifying `hmac_key` causes the set of accepted signature algorithms to be restricted to HMAC only, if not already restricted by the user. | ||||
| CVE-2025-46414 | 1 Eg4 Electronics | 7 Eg4 12000xp, Eg4 12kpv, Eg4 18kpv and 4 more | 2026-04-15 | 8.1 High |
| The affected product does not limit the number of attempts for inputting the correct PIN for a registered product, which may allow an attacker to gain unauthorized access using brute-force methods if they possess a valid device serial number. The API provides clear feedback when the correct PIN is entered. This vulnerability was patched in a server-side update on April 6, 2025. | ||||
| CVE-2025-2171 | 1 Aviatrix | 1 Controller | 2026-04-15 | N/A |
| Aviatrix Controller versions prior to 7.1.4208, 7.2.5090, and 8.0.0 do not enforce rate limiting on password reset attempts, allowing adversaries to brute force guess the 6-digit password reset PIN | ||||
| CVE-2024-31206 | 2026-04-15 | 8.2 High | ||
| dectalk-tts is a Node package to interact with the aeiou Dectalk web API. In `dectalk-tts@1.0.0`, network requests to the third-party API are sent over HTTP, which is unencrypted. Unencrypted traffic can be easily intercepted and modified by attackers. Anyone who uses the package could be the victim of a man-in-the-middle (MITM) attack. The network request was upgraded to HTTPS in version `1.0.1`. There are no workarounds, but some precautions include not sending any sensitive information and carefully verifying the API response before saving it. | ||||
| CVE-2024-23815 | 1 Siemens | 1 Desigo Cc | 2026-04-15 | 7.5 High |
| A vulnerability has been identified in Desigo CC (All versions if access from Installed Clients to Desigo CC server is allowed from networks outside of a highly protected zone), Desigo CC (All versions if access from Installed Clients to Desigo CC server is only allowed within highly protected zones). The affected server application fails to authenticate specific client requests. Modification of the client binary could allow an unauthenticated remote attacker to execute arbitrary SQL queries on the server database via the event port (default: 4998/tcp) | ||||
| CVE-2025-5864 | 2026-04-15 | 3.7 Low | ||
| A vulnerability was found in Tenda TDSEE App up to 1.7.12. It has been declared as problematic. Affected by this vulnerability is an unknown functionality of the file /app/ConfirmSmsCode of the component Password Reset Confirmation Code Handler. The manipulation leads to improper restriction of excessive authentication attempts. The attack can be launched remotely. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. Upgrading to version 1.7.15 is able to address this issue. It is recommended to upgrade the affected component. | ||||
| CVE-2025-40816 | 1 Siemens | 2 Logo!, Siplus Logo! | 2026-04-15 | 7.6 High |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable. | ||||
| CVE-2022-43110 | 1 Voltronicpower | 1 Viewpower | 2026-04-15 | 9.8 Critical |
| Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down. | ||||
| CVE-2025-5187 | 1 Kubernetes | 1 Kubernetes | 2026-04-15 | 6.7 Medium |
| A vulnerability exists in the NodeRestriction admission controller in Kubernetes clusters where node users can delete their corresponding node object by patching themselves with an OwnerReference to a cluster-scoped resource. If the OwnerReference resource does not exist or is subsequently deleted, the given node object will be deleted via garbage collection. | ||||
| CVE-2025-11852 | 1 Apeman | 1 Apeman | 2026-04-15 | 5.3 Medium |
| A vulnerability was found in Apeman ID71 218.53.203.117. The impacted element is an unknown function of the file /onvif/device_service of the component ONVIF Service. Performing manipulation results in missing authentication. The attack is possible to be carried out remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2025-9971 | 1 Planet | 1 Planet | 2026-04-15 | 9.8 Critical |
| Certain models of Industrial Cellular Gateway developed by Planet Technology have a Missing Authentication vulnerability, allowing unauthenticated remote attackers to manipulate the device via a specific functionality. | ||||
| CVE-2024-8462 | 2026-04-15 | 3.7 Low | ||
| A vulnerability was found in Windmill 1.380.0. It has been classified as problematic. Affected is an unknown function of the file backend/windmill-api/src/users.rs of the component HTTP Request Handler. The manipulation leads to improper restriction of excessive authentication attempts. It is possible to launch the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. Upgrading to version 1.390.1 is able to address this issue. The patch is identified as acfe7786152f036f2476f93ab5536571514fa9e3. It is recommended to upgrade the affected component. | ||||
| CVE-2025-24924 | 2026-04-15 | 9.8 Critical | ||
| Certain functionality within GMOD Apollo does not require authentication when passed with an administrative username | ||||
| CVE-2025-59097 | 1 Dormakaba | 1 Access Manager | 2026-04-15 | N/A |
| The exos 9300 application can be used to configure Access Managers (e.g. 92xx, 9230 and 9290). The configuration is done in a graphical user interface on the dormakaba exos server. As soon as the save button is clicked in exos 9300, the whole configuration is sent to the selected Access Manager via SOAP. The SOAP request is sent without any prior authentication or authorization by default. Though authentication and authorization can be configured using IPsec for 92xx-K5 devices and mTLS for 92xx-K7 devices, it is not enabled by default and must therefore be activated with additional steps. This insecure default allows an attacker with network level access to completely control the whole environment. An attacker is for example easily able to conduct the following tasks without prior authentication: - Re-configure Access Managers (e.g. remove alarming system requirements) - Freely re-configure the inputs and outputs - Open all connected doors permanently - Open all doors for a defined time interval - Change the admin password - and many more Network level access can be gained due to an insufficient network segmentation as well as missing LAN firewalls. Devices with an insecure configuration have been identified to be directly exposed to the internet. | ||||
| CVE-2025-3759 | 2026-04-15 | N/A | ||
| Endpoint /cgi-bin-igd/netcore_set.cgi which is used for changing device configuration is accessible without authentication. This poses a significant security threat allowing for e.g: administrator account hijacking or AP password changing. The vendor was contacted early about this disclosure but did not respond in any way. | ||||