Export limit exceeded: 110802 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (110802 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-25048 | 1 Ibm | 1 Mq Appliance | 2025-07-03 | 7.5 High |
| IBM MQ Appliance 9.3 CD and LTS are vulnerable to a heap-based buffer overflow, caused by improper bounds checking. A remote authenticated attacker could overflow a buffer and execute arbitrary code on the system or cause the server to crash. IBM X-Force ID: 283137. | ||||
| CVE-2024-10013 | 2 Progress, Progress Software | 2 Telerik Ui For Winforms, Progress Telerik Ui For Wpf Versions | 2025-07-03 | 7.8 High |
| In Progress Telerik UI for WinForms versions prior to 2024 Q4 (2024.4.1113), a code execution attack is possible through an insecure deserialization vulnerability. | ||||
| CVE-2025-0332 | 1 Progress | 1 Telerik Ui For Winforms | 2025-07-03 | 7.8 High |
| In Progress® Telerik® UI for WinForms, versions prior to 2025 Q1 (2025.1.211), using the improper limitation of a target path can lead to decompressing an archive's content into a restricted directory. | ||||
| CVE-2024-3892 | 1 Progress | 1 Telerik Ui For Winforms | 2025-07-03 | 7.2 High |
| A local code execution vulnerability is possible in Telerik UI for WinForms beginning in v2021.1.122 but prior to v2024.2.514. This vulnerability could allow an untrusted theme assembly to execute arbitrary code on the local Windows system. | ||||
| CVE-2025-20170 | 1 Cisco | 2 Ios, Ios Xe | 2025-07-03 | 7.7 High |
| A vulnerability in the SNMP subsystem of Cisco IOS Software and Cisco IOS XE Software could allow an authenticated, remote attacker to cause a DoS condition on an affected device. This vulnerability is due to improper error handling when parsing SNMP requests. An attacker could exploit this vulnerability by sending a crafted SNMP request to an affected device. A successful exploit could allow the attacker to cause the device to reload unexpectedly, resulting in a DoS condition. This vulnerability affects SNMP versions 1, 2c, and 3. To exploit this vulnerability through SNMP v2c or earlier, the attacker must know a valid read-write or read-only SNMP community string for the affected system. To exploit this vulnerability through SNMP v3, the attacker must have valid SNMP user credentials for the affected system. | ||||
| CVE-2025-20171 | 1 Cisco | 2 Ios, Ios Xe | 2025-07-03 | 7.7 High |
| A vulnerability in the SNMP subsystem of Cisco IOS Software and Cisco IOS XE Software could allow an authenticated, remote attacker to cause a DoS condition on an affected device. This vulnerability is due to improper error handling when parsing SNMP requests. An attacker could exploit this vulnerability by sending a crafted SNMP request to an affected device. A successful exploit could allow the attacker to cause the device to reload unexpectedly, resulting in a DoS condition. This vulnerability affects SNMP versions 1, 2c, and 3. To exploit this vulnerability through SNMP v2c or earlier, the attacker must know a valid read-write or read-only SNMP community string for the affected system. To exploit this vulnerability through SNMP v3, the attacker must have valid SNMP user credentials for the affected system. | ||||
| CVE-2025-20172 | 1 Cisco | 3 Ios, Ios Xe, Ios Xr | 2025-07-03 | 7.7 High |
| A vulnerability in the SNMP subsystem of Cisco IOS Software, Cisco IOS XE Software, and Cisco IOS XR Software could allow an authenticated, remote attacker to cause a DoS condition on an affected device. This vulnerability is due to improper error handling when parsing SNMP requests. An attacker could exploit this vulnerability by sending a crafted SNMP request to an affected device. For Cisco IOS and IOS XE Software, a successful exploit could allow the attacker to cause the device to reload unexpectedly, resulting in a DoS condition. For Cisco IOS XR Software, a successful exploit could allow the attacker to cause the SNMP process to restart, resulting in an interrupted SNMP response from an affected device. Devices that are running Cisco IOS XR Software will not reload. This vulnerability affects SNMP versions 1, 2c, and 3. To exploit this vulnerability through SNMP v2c or earlier, the attacker must know a valid read-write or read-only SNMP community string for the affected system. To exploit this vulnerability through SNMP v3, the attacker must have valid SNMP user credentials for the affected system. | ||||
| CVE-2025-20173 | 1 Cisco | 2 Ios, Ios Xe | 2025-07-03 | 7.7 High |
| A vulnerability in the SNMP subsystem of Cisco IOS Software and Cisco IOS XE Software could allow an authenticated, remote attacker to cause a DoS condition on an affected device. This vulnerability is due to improper error handling when parsing SNMP requests. An attacker could exploit this vulnerability by sending a crafted SNMP request to an affected device. A successful exploit could allow the attacker to cause the device to reload unexpectedly, resulting in a DoS condition. This vulnerability affects SNMP versions 1, 2c, and 3. To exploit this vulnerability through SNMP v2c or earlier, the attacker must know a valid read-write or read-only SNMP community string for the affected system. To exploit this vulnerability through SNMP v3, the attacker must have valid SNMP user credentials for the affected system. | ||||
| CVE-2025-20174 | 1 Cisco | 2 Ios, Ios Xe | 2025-07-03 | 7.7 High |
| A vulnerability in the SNMP subsystem of Cisco IOS Software and Cisco IOS XE Software could allow an authenticated, remote attacker to cause a DoS condition on an affected device. This vulnerability is due to improper error handling when parsing SNMP requests. An attacker could exploit this vulnerability by sending a crafted SNMP request to an affected device. A successful exploit could allow the attacker to cause the device to reload unexpectedly, resulting in a DoS condition. This vulnerability affects SNMP versions 1, 2c, and 3. To exploit this vulnerability through SNMP v2c or earlier, the attacker must know a valid read-write or read-only SNMP community string for the affected system. To exploit this vulnerability through SNMP v3, the attacker must have valid SNMP user credentials for the affected system. | ||||
| CVE-2025-20175 | 1 Cisco | 2 Ios, Ios Xe | 2025-07-03 | 7.7 High |
| A vulnerability in the SNMP subsystem of Cisco IOS Software and Cisco IOS XE Software could allow an authenticated, remote attacker to cause a DoS condition on an affected device. This vulnerability is due to improper error handling when parsing SNMP requests. An attacker could exploit this vulnerability by sending a crafted SNMP request to an affected device. A successful exploit could allow the attacker to cause the device to reload unexpectedly, resulting in a DoS condition. This vulnerability affects SNMP versions 1, 2c, and 3. To exploit this vulnerability through SNMP v2c or earlier, the attacker must know a valid read-write or read-only SNMP community string for the affected system. To exploit this vulnerability through SNMP v3, the attacker must have valid SNMP user credentials for the affected system. | ||||
| CVE-2025-20176 | 1 Cisco | 2 Ios, Ios Xe | 2025-07-03 | 7.7 High |
| A vulnerability in the SNMP subsystem of Cisco IOS Software and Cisco IOS XE Software could allow an authenticated, remote attacker to cause a DoS condition on an affected device. This vulnerability is due to improper error handling when parsing SNMP requests. An attacker could exploit this vulnerability by sending a crafted SNMP request to an affected device. A successful exploit could allow the attacker to cause the device to reload unexpectedly, resulting in a DoS condition. This vulnerability affects SNMP versions 1, 2c, and 3. To exploit this vulnerability through SNMP v2c or earlier, the attacker must know a valid read-write or read-only SNMP community string for the affected system. To exploit this vulnerability through SNMP v3, the attacker must have valid SNMP user credentials for the affected system. | ||||
| CVE-2018-9372 | 1 Google | 1 Android | 2025-07-03 | 7.8 High |
| In cmd_flash_mmc_sparse_img of dl_commands.c, there is a possible out of bounds write due to a missing bounds check. This could lead to a local escalation of privilege in the bootloader with no additional execution privileges needed. User interaction is not needed for exploitation. | ||||
| CVE-2018-9409 | 1 Google | 1 Android | 2025-07-03 | 7.8 High |
| In HWCSession::SetColorModeById of hwc_session.cpp, there is a possible out of bounds write due to a missing bounds check. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. | ||||
| CVE-2018-9375 | 1 Google | 1 Android | 2025-07-03 | 7.8 High |
| In multiple functions of UserDictionaryProvider.java, there is a possible way to add and delete words in the user dictionary due to a confused deputy. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. | ||||
| CVE-2024-25659 | 2 Infinera, Nokia | 2 Tnms, Transcend Network Management System | 2025-07-03 | 7.2 High |
| In Infinera TNMS (Transcend Network Management System) 19.10.3, an insecure default configuration of the internal SFTP server on Linux servers allows remote attacker to access files and directories outside the SFTP user home directory. | ||||
| CVE-2023-4358 | 3 Debian, Fedoraproject, Google | 3 Debian Linux, Fedora, Chrome | 2025-07-03 | 8.8 High |
| Use after free in DNS in Google Chrome prior to 116.0.5845.96 allowed a remote attacker to potentially exploit heap corruption via a crafted HTML page. (Chromium security severity: Medium) | ||||
| CVE-2023-40072 | 1 Elecom | 4 Wab-s300, Wab-s300 Firmware, Wab-s600-ps and 1 more | 2025-07-03 | 8.8 High |
| OS command injection vulnerability in ELECOM wireless LAN access point devices allows an authenticated user to execute an arbitrary OS command by sending a specially crafted request. | ||||
| CVE-2024-42902 | 1 Limesurvey | 1 Limesurvey | 2025-07-03 | 8.8 High |
| An issue in the js_localize.php function of LimeSurvey v6.6.2 and before allows attackers to execute arbitrary code via injecting a crafted payload into the lng parameter of the js_localize.php function | ||||
| CVE-2024-41435 | 1 Yugabyte | 1 Yugabytedb | 2025-07-03 | 7.5 High |
| YugabyteDB v2.21.1.0 was discovered to contain a buffer overflow via the "insert into" parameter. | ||||
| CVE-2024-41436 | 1 Clickhouse | 1 Clickhouse | 2025-07-03 | 7.5 High |
| ClickHouse v24.3.3.102 was discovered to contain a buffer overflow via the component DB::evaluateConstantExpressionImpl. | ||||